EasyManua.ls Logo

Endress+Hauser Proline Promass 83 - Temperature Table Compact Version

Endress+Hauser Proline Promass 83
48 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0ATEX II3G Proline Promass 83, 84
24 Endress+Hauser
Temperature table
compact version
Max. medium temperature [°C] for T1-T6 in relation to the maximum ambient temperature T
a
For sensors classified Ex nR:
)
1)
as well as DN 15 FB, DN 25 FB, 40 FB and 50 FB (FB = Full bore)
For sensors classified Ex nL:
() = The maximum permissible medium temperatures apply only when the transmitter is installed in such a
way that it is not above the sensor and there is free convection on all sides.
The minimum me
dium temperature is –50 °C for Promass A/F/H/I/M/O/P/S/X, 
and –40 °C for Promass E.
The minimum ambient temperature is –20 °C.
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*A**-… DN 1...4 +60 °C – 95 130 190 200 200
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*E**-… DN 8...80 +60 °C – 95 130 140 140 140
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*F**-… DN 8...250 +60 °C – 95 130 (190) (200) (200)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*F**-1…
Promass 8*F**-2…
Promass 8*F**-3…
Promass 8*F**-4…
DN 25, 
DN 50, 
DN 80
+60 °C – 95 130 (190) (290) (350)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*H**-… DN 8…50 +60 °C – 95 130 (190) (200) (200)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*I**-… DN 8...80
1)
+60 °C – 95 130 (150) (150) (150)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*M**-… DN 8…80 +60 °C – 95 130 150 150 150
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*P**-… DN 8…50 +60 °C – 95 130 (190) (200) (200)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*S**-… DN 8…50 +60 °C – 95 130 (190) (200) (200)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*O**-…
DN 80, 100
+60 °C
– 80 110 (185) (200) (200)
DN 150 – 80 110 (180) (200) (200)
DN T
a
T6
(85 °C)
T5
(100 °C)
T4
(135 °C)
T3
(200 °C)
T2
(300 °C)
T1
(450 °C)
Promass 8*X**-… DN 350 +60 °C – 90 125 (190) (200) (200)

Table of Contents

Other manuals for Endress+Hauser Proline Promass 83