Technical data Proline Promass F 100 Modbus RS485
100
Cable entries Cable gland: M20 × 1.5 with cable 6 to 12 mm (0.24 to 0.47 in)
Thread for cable entry:
M20
G ½"
NPT ½"
Cable specification →  28
16.6 Performance characteristics
reference operating
conditions
Error limits based on ISO 11631
Water with +15 to +45 °C (+59 to +113 °F) at2 to 6 bar (29 to 87 psi)
Specifications as per calibration protocol
Accuracy based on accredited calibration rigs that are traced to ISO 17025.
To obtain measured errors, use the Applicator sizing tool →  92
Maximum measured error o.r. = of reading; 1 g/cm³ = 1 kg/l; T = medium temperature
Base accuracy
Design fundamentals →  104
Mass flow and volume flow (liquids)
±0.05 % o.r. (PremiumCal; order code for "Calibration flow", option D, for mass flow)
±0.10 % o.r.
Mass flow (gases)
±0.35 % o.r.
Density (liquids)
Under
reference operating conditions
Standard density
calibration
1)
Wide-range
Density specification
2) 3)
[g/cm³] [g/cm³] [g/cm³]
±0.0005 ±0.01 ±0.001
1) Valid over the entire temperature and density range
2) Valid range for special density calibration: 0 to 2 g/cm³, +5 to +80 °C (+41 to +176 °F)
3) Order code for "Application package", option EF "Special density"
Temperature
±0.5 °C ± 0.005 · T °C (±0.9 °F ± 0.003 · (T – 32) °F)