Proline Promass P 300
Endress+Hauser 37
Pulse/frequency output
1
2
3
12345
A0028761
 13 Connection example for pulse/frequency output (passive)
1 Automation system with pulse/frequency input (e.g. PLC)
2 Power supply
3 Transmitter: Observe input values →  14
Switch output
1
2
3
A0028760
 14 Connection example for switch output (passive)
1 Automation system with switch input (e.g. PLC)
2 Power supply
3 Transmitter: Observe input values →  14
Double pulse output
1
2
3
4
A0029280
 15 Connection example for double pulse output (active)
1 Automation system with double pulse input (e.g. PLC)
2 Transmitter: Observe input values →  16
3 Double pulse output
4 Double pulse output (slave), phase-shifted

Table of Contents