Ditec ION4-ION6
Sliding gates
(translation of the original instructions)
www.entrematic.com
IP2288EN • 2019-04-10
Technical Manual

Table of Contents

Questions and Answers

  • E
    ewingronaldAug 5, 2025
    Why does Entrematic Other remote control have limited range?
    • J
      Jeffrey AdkinsAug 5, 2025
      If your Entrematic Other remote control has a limited range or doesn't work when the automation is moving, it could be due to radio transmission being impeded by metal structures or reinforced concrete walls. Try installing the antenna outside. Also, consider replacing the transmitter batteries.
  • K
    kathrynvelezAug 9, 2025
    How to fix Entrematic Ditec ION4 control panel that does not switch on?
    • C
      Cassidy CollierAug 9, 2025
      If the Entrematic Other control panel doesn't switch on, the most likely cause is a lack of power supply. Check the power supply cable and the related wiring.
  • J
    Joseph Hughes MDAug 13, 2025
    What to do if Entrematic Other remote control does not work?
    • D
      Daniel JohnsonAug 13, 2025
      If the Entrematic Other remote control isn't working, the issue might be due to a missing or incorrect storage module. Turn off the automation and plug in the correct storage module. Also, check the correct memorisation of the transmitters on the built-in radio. If there is a fault with the radio receiver that is built into the control panel, the remote control codes can be read by removing the storage module.
  • D
    Daniel WilsonAug 18, 2025
    What to do if Entrematic Ditec ION4 flashing light is not working?
    • P
      patrickcookAug 18, 2025
      If the flashing light on your Entrematic Other is not working, check the connections to ensure the wires of the flashing light are not detached or short-circuited.
  • Y
    ybrownAug 22, 2025
    What to do if Entrematic Ditec ION4 Other automation opens/closes briefly and then stops?
    • R
      Regina PriceAug 22, 2025
      If your Entrematic Other automation opens or closes briefly and then stops, it might be due to friction. Manually check that the automation moves freely and check the adjustment.
  • N
    Nathan ThomasAug 27, 2025
    Why Entrematic Ditec ION4 Other external safety devices are not activated?
    • A
      Aaron MckenzieAug 27, 2025
      If the external safety devices on your Entrematic Other are not activating, it could be due to incorrect connections between the photocells and the control panel. Check that / is displayed. Connect NC safety contacts together in series and remove any jumpers on the control panel terminal board.
  • J
    Joshua MurrayOct 31, 2025
    What to do if Entrematic Other automation does not open or close?
    • M
      Michael TerryOct 31, 2025
      If your Entrematic Other automation isn't opening or closing, several factors could be at play. First, check the power supply cable to ensure there's power. Also, a blown line fuse could be the culprit, so try replacing it. Safety contacts might be open, so verify they are correctly closed (NC). If you have accessories, a short circuit could be the issue; disconnect them one by one from terminals 0-1, ensuring a 24V= voltage is present. Reconnect them individually to identify the problem. Make sure photocells are clean and working properly. Also, confirm that the hatch is closed correctly and the release microswitch makes contact. Finally, check the connection of the limit switches. If none of these steps resolve the issue, there may be a motor or mechanical fault, in which case you should...

Summary

General Safety Precautions

General Safety Precautions

User Safety Precautions

Essential safety information for users regarding installation, use, and maintenance.

Declaration of Incorporation

Machinery Directive Compliance

Installer obligations regarding the Machinery Directive (2006/42/EC) for door/gate motorisation.

Technical Specifications

Standard Installation Guide

Product Dimensions

Main Components Identification

Installation Procedures

Preliminary Installation Checks

Ensuring gate stability, guide alignment, and proper stop fitting before installation.

Base Plate Positioning and Mounting

Instructions for preparing and positioning the concrete base and mounting plate.

Installation Procedures

Virtual Encoder Operation

Explanation of how the virtual encoder manages gate movement and end stops.

Optional Accessories Installation

Guides for installing magnetic limit switches, battery kit, and remote release handle.

Electrical Connections Guide

LCU48 Control Card Overview

Navigating Control Panel Menus

Display On;Off Control

Procedure for switching the control panel display on and off.

Control Panel Navigation Keys

Explanation of how to use the navigation keys for commands and parameter setting.

Navigating Control Panel Menus

Control Panel Menu Structure

Visual overview of the menu hierarchy and available parameters for configuration.

Product Initial Setup

WZ Configuration Wizard Menu

Guided setup process for initial product configuration using the WZ wizard.

Control Panel Commands

Outputs and Accessories Management

Jumper Settings Configuration

Parameter Adjustments Guide

Main Adjustment Menu Overview

Description of the main menu categories for control panel adjustments.

Parameter Adjustments Guide

Automatic Configurations Menu (AT)

Managing automatic configurations, predefined settings for residential and condominium use.

Parameter Adjustments Guide

Basic Configurations Menu (BC)

Setting basic automation parameters like automatic closure, status, and anti-freeze.

Parameter Adjustments Guide

Additional BC Parameters

Advanced basic configuration options including operator presence and command types.

Parameter Adjustments Guide

Basic Adjustment Menu (BA)

Adjusting automatic closing times, opening/closing speeds, and thrust settings.

Parameter Adjustments Guide

Additional BA Adjustment Parameters

Fine-tuning obstacle recognition, start times, and deceleration ramps.

Parameter Adjustments Guide

Radio Operations Menu (RO)

Managing remote control storage, visualization, and maximum number of codes.

Parameter Adjustments Guide

Additional RO Parameters for Remote Control

Configuring functions for stored remote control channels (CH1-CH4).

Parameter Adjustments Guide

Special Functions Menu (SF)

Managing firmware versions, saving/loading configurations, and setting passwords.

Parameter Adjustments Guide

Additional SF Parameters for Security

Setting and deleting passwords, managing alarm counters and logs.

Parameter Adjustments Guide

Cycles Counter Menu (CC)

Displaying total and partial operation counts, and power supply hours.

Parameter Adjustments Guide

Additional CC Parameters for Maintenance

Configuring maintenance alarms and selecting display modes for alarm messages.

Energy Management Menu (EM)

Managing solar panel power supply and energy-saving features.

Parameter Adjustments Guide

Additional EM Parameters for Battery Status

Setting battery voltage thresholds and selecting battery operation modes.

Advanced Parameters Menu (AP)

Advanced settings for limit switches, device connections, and obstacle detection.

Display Signals and Status

Automation Status Display

Interpreting display codes for automation status like closed, open, or stopped.

Display Signals and Status

Safety Device and Command Display

Understanding display codes for safety devices, commands, and radio reception.

Display Signals and Status

Alarms and Faults Visualization

Interpreting alarm codes for mechanical issues, motor faults, and safety device errors.

Troubleshooting Common Issues

Entrematic Ditec ION4 Specifications

General IconGeneral
Motor voltage24 V DC
Max. leaf weight400 kg
Operating temperature-20°C to +55°C
Protection classIP54
Protection RatingIP54