21
IP2288EN
EN
13. Outputs and accessories
Output
Value of
accessories
Description
0
-
1
+
24V / 0.3A
Power supply to accessories
Output for power supply to external accessories.
NB: the maximum absorption of 0.3A corresponds to the sum of all
terminals 1.
GOL148REA
If the ZENPRS radio receiver is used (868.35 MHz), connect the supplied
antenna wire (90mm).
+LP-
FLM
FL24
24V / 25W
Flashing light
The pre-ο¬ashing settings can be selected from the third level menu
β and/or β .
To modify the operating mode of the LP output, refer to the selection
β .
AUX
SOFA1-SOFA2
GOPAVRS
LAB9
BIXR2
BIXPR2
LAN7S
The control panel has a slot for plug-in command and safety cards.
The action of the control card can be deο¬ned by selecting
β .
When using slot-in radio boards, remove the RDX module. The display
will show
.
WARNING: the plug-in board must be inserted and removed with the
power supply disconnected.
12.1 SOFA1-SOFA2 or GOPAVRS self-controlled safety edge
Command Function Description
GOPAV
SOFA1-SOFA2
SAFETY TEST
Insert the SOFA1-SOFA2 or GOPAVRS device in the slot
for plug-in boards AUX1 or AUX2.
If the test fails, an alarm message appears on the
display.
1
6
NC SAFETY STOP
When selecting
β β , connect the output
contact of the safety device to terminals 1-6 on the con-
trol panel (in series with the photocell output contact,
if installed).
1
8
NC
CLOSURE
SAFETY DEVICE
When selecting
β β , connect the output
contact of the safety device to terminals 1-8 on the con-
trol panel (in series with the photocell output contact,
if installed).
1
6
8
NC
CLOSING/
OPENING
SAFETY DEVICE
When selecting
β β , connect the output
contact of the safety device to terminals 1-6-8 on the
control panel (in series with the photocell output con-
tact, if installed).
If
β , and cannot be or .