32
IP2288EN
EN
Display Description
Selections
available
ER - Deletion of a single remote control
→→
2”
EA - Total memory deletion
→→
2” 2”
RE - Setting memory opening from remote control
OF - Disabled
ON - Enabled When enabled (ON), the remote programming is activated.
To store new remote controls without using the control panel, refer to the remote
control instructions.
NB: make sure you do not accidentally memorise unwanted remote controls.
EP -Setting the coded area messages
If the possibility to receive coded messages is enabled, the control pan-
el will be compatible with remote controls of the “ENCRYPTED” type.
RO
15.6 Second level menu - SF (Special Functions)
Display Description
CU - Visualisation of the firmware version on the control panel
→→→ Release 1.1 [esempio]
SV - Saving user conguration on control panel storage module.
[esempio]
2”
→→ →→
By selecting you can save up to 2 personalised configu-
rations in memory positions
and only with the storage module
present on the control panel.
WARNING: if is selected, no user conguration can be
saved on
and .
WARNING: if the display visualises
flashing, the memory module
may not be installed.
Selections
available
RC - Configuration loading
[esempio]
2”
→→ →→
It's possible to load the user configurations previously stored and
on the memory module of the control panel.
SF - Special Functions
(example)
(example)
(example)