15.3.1 Additional BC level parameters that can be configured
(available with enabled)
Display Description
Selections
available
HR - Enabling of "operator present" function
ON - Enabled
OF - Disabled
NB: Set
only if and .
WARNING:
If the OPERATOR PRESENT function is activated, make sure that no-
one is near the automation when an opening or closing command is
given.
• The actuation device for the OPERATOR PRESENT function must be
placed within the visibility of the guided part but away from the moving
parts.
It must also be installed at a minimum height of 1.5 m and be placed out
of the public’s reach.
C5 - Operation of command associated with contact 30-5
1-5 - Step-by-step
1-3 - Opening
64 - Functioning of safety stop/closing command.
1-4 - Closing
1-6 - Safety stop
RM - Radio receiver operation
1-5 - Step-by-step
1-3 - Opening
AM - Operation of AUX1 plug-in control board
1-5 - Step-by-step
1-3 - Opening
MP - Start-up at maximum power
ON - During start-up it increases the thrust on obstacles to maximum
OFF - During start-up, the thrust on obstacles is the one adjusted
by
- .
PP - Setting step-by-step sequence from command 1-5.
ON - Opening-Stop-Closing-Stop-Opening
OF - Opening-Stop-Closing-Opening
S5 - Duration of STOP in step-by-step sequence from command
1-5.
ON - Permanent
OF - Temporary