15.3 Second level menu - BC (Basic Configurations)
Display Description
Selections
available
AC - Enabling of automatic closure
ON - Enabled
1-2 - Dependent on input 1-2
SS - Selection of automation status at start
OP - Open
CL - Closed
Indicates how the control panel considers the automation at the
time of switch-on, or after a POWER RESET command.
SO - Enabling of reversal safety contact functioning
ON - Enabled
OF - Disabled
When enabled (ON) with the automation idle, if the contact 1-8 is open, all
operations are prevented.
When disabled (OF) with the automation idle, if the contact 1-8 is open, opening
operations are permitted.
NI - Enabling of NIO electronic anti-freeze system
ON - Enabled
OF - Disabled
When enabled (ON), it maintains the efciency of the motor even at low ambi-
ent temperatures.
NB: for correct operation, the control panel must be exposed to the same am-
bient temperature as the motors.
The intervention temperature for NIO can be set by selecting
.
BC - Basic configurations