EN
Problem Possible cause Alarm
signalling
Operation
The remote control
has limited range
and does not work
with the auto-
mation moving.
The radio transmission is im-
peded by metal structures and
reinforced concrete walls.
Install the antenna outside.
Replace the transmitter batteries.
The remote control
does not work
No storage module or incor-
rect storage module.
Switch the automation off and plug in the
correct storage module.
Check the correct memorisation of the
transmitters on the built-in radio. If there
is a fault with the radio receiver that is
built into the control panel, the remote
control codes can be read by removing
the storage module.
The flashing light
is not working
The wires of the flashing light
are detached or have short
circuited.
Check the connections.
If the problem persists, contact Techni-
cal Service.