EN-44 Installation and Operating Instructions - EOS Vision
Service and maintenance
EN
Replacing the tubular heating elements
1 Remove the heating coil.
Removing the heating coil, EN-41
2 Identify the defective heating element by taking measurements.
3 Remove both flat plugs from the defective heating element.
4 Loosen the 2 fixing nuts and serrated washers on the defective heating
element.
5 Press the heating element slightly backwards and remove it upwards.
6 Insert the new heating element.
7 Fix the heating element with the serrated washers and the fixing nuts.
8 Plug in the flat plug.
Check the wiring on all heating elements before reclosing the termi-
nal box and setting up the heater.
A Heating element B Flat pin
B
A