Epec CAN Module Family
2024 CONTROL MODULE
31 / 34
07.10.2010
2024G08,G18 / MAN000185
Epec Oy reserves all rights for improvements without prior notice
Epec Oy Postiosoite/Postal address Puhelin/Phone Fax Internet
Tiedekatu 6 PL/P.O.Box 194 +358-(0)20-7608 111 +358-(0)20-7608 110 www.epec.fi
FIN-60320 Seinäjoki FIN-60101 Seinäjoki, Finland
6.3 Environmental Tests
The following environmental tests have been performed to Epec 4G modules:
Temperature
Test Temperature
Duration/
Exposure
time
Remarks
Cold
IEC 60068-2-1,
Test Ab
-45 °C 16 h -
Dry heat
IEC 60068-2-2,
Test Bb
70 °C 16 h -
Damp heat cycling
IEC 60068-2-30,
Test Db
+25 °C/+55 °C
• rel. humidity >90%
• six test cycles
Change of temperature
IEC 60068-2-14,
Test Na
-50 °C/+60 °C 3 h
change of temperature 10
°C/min
• 2 test cycles
Mechanical resistance
Test
Duration and
direction
Remark
Shock/Bump test IEC
60068-2-27, and -29,
Tests Ea and Eb
• pulse duration 6
ms
• 500 impulses in
every six
directions
• half sine pulse shape
• peak acceleration 500 m/s
2
Vibration, random
IEC 60068-2-64,
Test Fh
• test duration 60
min in every
three test
direction
• ASD-level 0,5 m
2
/s
3
, 10 … 200 Hz
• ASD-level 1,0 m
2
/s
3
, 200 … 500 Hz
• total spectral acceleration 3,54 grms
Free fall,
IEC 60068-2-32,
Test Ed
• one fall /
direction
on each surface
and corner
• fall height 100 cm
Corrosion
Test Temperature Duration Concentration
Salt spray test
ISO 9227
+35 °C 24 h 50 g/l, NaCl