Error 17 Checksum error of the recorded piece.
The second number is the running number of
the piece.
Error 18 Checksum error in the tree list.
The second number is the number of the
preselection line for which the piece has been
made.
Error 24 The piece list has been damaged.
No correction possibilities.
If the length is calibrated without a proper pulse value, the calibration
routine gives the following error message:
Error 60 Calibration trial with negative pulse value.
Error 61 Calibration trial with too small pulse value.
Error 62 Calibration trial of the diameter sensor with
negative pulse value. The signal wires A and B
of the diameter sensor maybe crossed.
Error in head parameter
Continue Y / N Correct calibration data is not received from the
grapple. May occur when the measuring
equipment is switched on. You can continue by
pressing Enter, after you have checked the
calibration data of the measuring equipment
and noted that it is correct.
The error message may be caused by:
− Contact to the grapple module is broken.
Check the voltages and the connections.
− New grapple module or new display module
has been changed, which has wrong
program version. Contact the equipment
seller.