Epson DFX-9000 Field Repair Guide 3/29/07
Adjustments Printer Component, Software Item, LCD Display, Printer Button Page 177.
15. If the .40mm feeler gauge will easily fit between the Print Head and the Platen, the gap is too wide. Loosen
Screw C about 1/8 of a turn. To adjust the gap, insert a flat blade screwdriver into the opening to the right of
Screw C. Twist the screwdriver to change the gap. To decrease the gap, move the Upper Angle Bar
downwards. Tighten Screw C when the adjustment is correct.
ScrewA
Screw B
Screw C