2-23
EMP-9000/8000
SEIKO EPSON Revision:A
2.8. IF Units
There are 11 interface connectors and audio controller. An audio signal outputs to the AU
board Assembly is selected with IC200 (Audio Controller).
Figure2-24
Remarks:
Because of DDC chip installation, there are no compatibility of IF panel unit with EMP-9000’s
and EMP8000’s.
CN100(PC•IN)CN101(PC•OUT)
CN202 CN201
CN300
CN300
CN302
J200
CN200
CN301
J201
Cable Assy AU•IN
Connect to Main bord Assy unit CN1004
Cable Assy PC•SEL
Connect to Mainboard Assy unit CN4
Cable Assy coaxial PC•OUT
Connect to Main board Assy
unit CN3
Cable Assy coaxial PC•IN
Connect to Main board Assy
unit CN2
Connect to Main board Assy
unit CN502