EMP-9000/8000
3-8Revision:A SEIKO EPSON
2. Remove the Air Filter
3.2.5. Front Case
1. Remove two screws fixing the Front Case.
2. Remove the tub in the upper side of Front Case on the indentation of Upper Case Unit then
detach the Front Case.
Figure3-6
3.2.6. Projection Lens
1. Remove four screws(Screw, HSH M4x8) fixing the Projection Lens by using exclusive use 6
corner wrench then take out Projection Lens from Optical Engine
Figure3-7
Screw
Screw