EMP-9000/8000
2-34Revision:A SEIKO EPSON
3. Lamp information control
Table 2-5 Lamp information
Lamp indicator EE-PROM Screen display etc.
Lamp running hours Keep total running
hours with lamp.
Ensure with information of
MENU display.
Exceed 1900 hours Blink in orange
Clear the
EE-PROM with
lamp replacement.
After the power on,
“Exchange lamp” message
appear on the screen.
Out of order (Lamp off) Blink in red Lamp goes off.
Number of turn on times Increment by one. Ensure with information of
MENU display.
Lamp total running hours with
EMP-5500
Keep total running
hours with EMP-7500.
Ensure with information of
MENU display.
Lamp exchange times Keep exchange times. Ensure with information of
MENU display.