EMP-9000/8000
4-6Revision:A SEIKO EPSON
Power ON / OFF
Figure4-4
Start
Press Power button on
the Operation panel.
Operation indicator
becomes lights in green?
Does Intake fan1/2
move?
Does power supply unit
A/B fan move?
Dose Exhaust fan
move?
Press Power switch on the switch
panel pushes down 30 second.
Does AC input voltage is
correct?
AC power is applied on
the interlock switch.
Remove the power cable.
Unplug the fast-on tab on
the safety switch.
Measure the safety switch
resistance.
Replace AC power
Filter unit A
Filter unit A
Press Power button by
the Remote controller .
Operation indicator
becomes lights in green?
Replace Vacuum fan
Does exhaust fan move?
Replace applicable
power supply unit.
Replace Exhaust fan
Dose Exhaust fan
move?
Safety switch resistance
is nearly zero ohm?
Fixed?
Go to start
Go to start
Go to start
Go to start
Go to start
Replace MA board
Replace power supply
unit A
Replace MA board
Replace Safety switch
A
No
Yes
Yes
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No

Table of Contents