5
9
Figure
3-2.
Printhead
Connector
Pin
Alignment
Table
3-2.
Printhead
Coil
Resistance
Test
Points
Common
Pin
No.
Test
Pin
No.
Test
Method
(Set
meter
to
ohms.
Disconnect
the
printhead
after
the
printer
is
powered
off.)
Meter
Reading
Refer
to
the
figure
below.
Refer
to
the
figure
below.
Place
one
lead
on
each
pin
and
the
other
lead
on
each
common
pin.
29.6±3.0
(at
25°C,
77°F)
Table
3-3.
Printhead
Driver
Test
Pin
Transistor
Numbers
Test
Method
(Set
meter
to
diodes.
Check
with
printer
power
off.)
Meter
Reading
Q2,
Q3,
Q4,
Q5,
Q6,Q7,
Q8,
Q9,
Q10,Q11,Q12,
Q13,
Q14,
Q15,
Q16,
Q17,
Q18,
Q19,
Q20
Check
the
following:
-From
the
base
to
the
collector
-From
the
base
to
the
emitter
Reverse
the
leads
and
test
again.
The
tester
shows
neither
open
nor
shorted.
3
15
C5
2C6
5
16 11
C7
17
C8 14 4 8
1
913
7
C1
18 C2
12
C3
C4
610
TT
XX
X
X
XX
R
F
R
F
F
COM. C1 C2 C3 C4
1.7.13 9 10.18 6.12
R
COM. C5 C6 C7 C8
2.5.11 3.15 16.17 4.8.14
Pin No, Pin No,
T : Thermistor terminal
X : Not used
Table
3-4.
Detector
Test
Point
Detector
Connector
Number
Test
Method
(Set
meter
to
ohms.
Check
with
printer
power
off.)
Meter
Reading
HP
Detector
(CN4)
Place
one
lead
on
pin
1
and
the
other
lead
on
pin
2,
and
toggle
the
detector
actuator.
Meter
should
toggle
between
open
and
short.
(LOW:
within
CR
Home
position.)
Front
PE
(FPE)
Detector
(CN6)
Place
one
lead
on
pin
1
and
the
other
lead
on
pin
2,
and
toggle
the
detector
actuator.
Meter
should
toggle
between
open
and
short.
(HIGH:
paper
is
installed
in
the
printer.)
Rear
PE
(RPE)
Detector
(CN7)
Place
one
lead
on
pin
1
and
the
other
lead
on
pin
2,
and
toggle
the
detector
actuator.
Meter
should
toggle
between
open
and
short.
(HIGH:
paper
is
installed
in
the
printer.)
Release
Lever
Detector
(CN5)
Place
one
lead
on
pin
1
and
the
other
lead
on
pin
2,
and
toggle
the
detector
actuator.
Meter
should
toggle
between
open
and
short.
(HIGH:
Friction
Feed
mode.)
PG
Detector
(CN8)
Place
one
lead
on
pin
1
and
the
other
lead
on
pin
2,
and
move
the
detector
actuator
from
-0
to
6.
Meter
should
toggle
between
open
and
short.
(HIGH:
PG
-
1
~
3.)
Printhead
thermistor
Place
one
lead
on
pin
T
and
the
other
lead
on
other
pin
T
to
check
the
resistance.(Refer
to
Fig.3-2.)
Approx.
14K
(at
17°C)