DISASSEMBLY AND ASSEMBLY Disassembly/Assembly Procedures 105
4.2.6.6 PictBridge Unit
1. Remove the Printer Mechanism. See section 4.2.1.5 on page 82.
2. Disconnect the PictBridge Unit Connector Cable from connector CN2 on the Main Board.
3. Remove the Acetate Tape and remove the PictBridge Unit from the Main Frame.
Figure 4-84. Removing the PictBridge Unit
A D J U S T M E N T
R E Q U I R E D
After replacing the parts listed below, be sure to apply G-26 or
G-71 grease to the area specified for each part.
Left and Right Parallelism Adjust Bushing (p.151)
Left and Right CR Scale Mounting Plate
(p.151)
Left and Right PG Cam
(p.152)
Left and Right PG Torsion Spring (p.152)
CR Guide Plate
(p.152)
Driven Pulley Holder
(p.153)
Carriage Shaft (p.152)
and “Lubrication of Carriage Shaft” on page 154.
After replacing or removing the Carriage Shaft and Carriage
Unit, the following adjustment must be performed.
1. PG Adjustment (p.132)
2. Head Angular Adjustment (p.132)
3. Bi-D Adjustment (p.132)
4. First dot position (p.133)
5. PW Sensor Adjustment (p.133)
Refer to Chapter 5 “Adjustment” for details on the adjustments.
C H E C K
P O I N T
Stylus Photo 1390 does not have the PictBridge Unit. Skip this
section for the model.
C A U T I O N
See the page given below to check for sharp metal edges before
starting maintenance/repair.
“Sharp Metal Edges” on page 75.