4.2.6.4 APG Assy
1. Remove the Upper Housing.
For Stylus Photo 1400/1410: See section 4.2.1.4 on page 80.
For Stylus Photo 1390: See section 4.3.1 on page 128.
2. Disconnect the APF Motor Cable from connector CN9 (red) on the Main Board
3. Remove the acetate tape, and remove the Cable from the ASF Assy.
4. Disconnect the Connector Cables from the two APG Sensor Connectors.
Figure 4-54. Disconnecting the Connector Cables
5. Remove the three C.B.S. 3x6 screws that secure the APG Assy and remove the
APG Assy from the Main Frame.
Figure 4-55. Removing the APG Assy
Tighten the screws in the order shown in Figure 4-52.
A D J U S T M E N T
R E Q U I R E D
After replacing or removing the Printhead, the following
adjustment must be performed.
1. PG Adjustment (p.132)
2. Head ID Input (only after replacing) (p.132)
3. Head Angular Adjustment (p.132)
4. Bi-D Adjustment (p.132)
5. First dot position (p.133)
6. PW Sensor Adjustment (p.133)
Refer to Chapter 5 “Adjustment” for details on the adjustments.
CN9
APG Motor
APG Assy
APG Sensor Connectors
Acetate Tape
3
1
2
2) C.B.S. 3x6
(8±1 kgf.cm)