4.3.3 CR Motor Unit
1. Remove the Scanner Unit (p.65)
2. Remove the Scanner Housing (p.77)
3. Remove the screw fastening the grounding wire. (Fig. 4-44)
4. Disconnect the CR Encoder cable, the CR Motor cable and the grounding wire
from the Housing Lower. (Fig. 4-44)
5. Remove the screw and washers (x4) securing the CR Motor Unit. (Fig. 4-45)
Figure 4-44. CR Motor Unit 1
Figure 4-45. CR Motor Unit 2
Take care in handling the Housing Lower, remembering that
grease is applied to the CR guide area of the Housing Lower.
Do not touch any parts with a greasy hand or part.
(Especially take great care in handling the Encoder Scale.)
Do not remove or loosen the screw marked with X for the CR
Motor Unit shown at right. Remember that the CR Motor Unit
must be replaced with a new one if the encoder is shifted from
the correct position. (Fig. 4-45)
When installing the CR Motor Unit on the Housing Lower,
push it adequately so that the insulators are compressed to such
thickness as shown below.
Route the cables as shown.
( Fig. 4-44, Fig. 4-45)
A
B
A<B
Push the unit until the
thickness of the insulator
A becomes smaller than
that of the insulator B,
and tighten the screw.
Secure the cables by wrapping
them once around the hooks.
C.B.(P2) 3x6 F/Zn-3C
Torque : 0.5±0.1N
·m
Grounding wire
CR Motor Unit
Do not remove or loosen
C.B.P-TITE 3x8 (x4)
Torque : 0.5±0.1N
·m
Here is grease