EPSON Stylus Photo RX585/RX595/RX610 Revision B
Disassembly and Assembly Disassembly and Assembly of Major Parts of Printer 88
4.5.5 CR Motor
1. Remove the Printer Mechanism (p.76)
2. At the rear of the printer, detach the cable of the CR Motor from the frame.
3. At the rear of the printer, remove the tension spring of the Driven Pulley Assy.
(Fig. 4-69)
4. Remove the screws (x2), and remove the CR Motor. (Fig. 4-70)
Figure 4-68. Removing the CR Motor Cable
Figure 4-69. Removing the Tension Spring
Figure 4-70. Removing the CR Motor
Lubrication is necessary. Refer to the following section and
lubricate the specified points:
LUBRICATION OF DRIVEN PULLEY (p.118)
Install the CR Motor with its printed area facing upward.
Install the Timing Belt with the tooth side facing inside and
without torsion.
When the CR Motor has been replaced with a new one, wind
acetate tape (18x20 mm) x3 around the harness as shown. (Fig.
4-68)
A D J U S T M E N T
R E Q U I R E D
Once the CR Motor has been reinstalled, refer to the following
section and perform the necessary adjustments.
5.2 Adjustment by Using Adjustment Program (p.101)
Hook (x3)
Acetate Tape (18x20mm) x3
Driven Pulley Assy
Tension Spring
C.P 3x4 (x2)
Torque : 0.4±0.1N
·m