EPSON Stylus Photo RX585/RX595/RX610 Revision B
Disassembly and Assembly Disassembly and Assembly of Major Parts of Printer 83
4.5 Disassembly and Assembly of Major Parts of
Printer
4.5.1 PF Motor, PF Encoder and PF Scale
1. Remove the Printer Mechanism (p.76)
2. Disconnect the FFC of the PF Encoder, remove the screw, and remove the PF
Encoder. (Fig. 4-56)
3. Remove the PF Scale. (Tape is stuck in the center circle area)
4. Release the lead wires of the PF Motor. (Fig. 4-62)
5. Remove the Harness Holder. (Fig. 4-57)
6. Remove the screws (x2) securing the PF Motor, and remove the PF Motor in the
lateral direction. (Fig. 4-58)
Figure 4-56. Removing the PF Encoder / PF Scale
Figure 4-57. Removing the Harness Holder
Figure 4-58. Removing the PF Motor
Handle the PF Scale with care not to scratch or stain it. Do not
touch it with your bare hand.
Install the PF Motor with its labeled area facing outward.
(Fig. 4-58)
When installing the PF Encoder, confirm that the reading area
does not come in contact with the PF Scale.
A D J U S T M E N T
R E Q U I R E D
Once the PF Motor has been reinstalled, refer to the following
section and perform the necessary adjustments.
5.2 Adjustment by Using Adjustment Program (p.101)
PF Scale and PF Encoder
C.B.P-TITE 2.6x8
Torque : 0.4±0.1N
·m
PF Encoder
FFC
PF Scale
Peel off the tape
Intermediate gear (26.5)
C.P.S-TITE 3x6 (x2)
Torque : 0.4±0.1N
·m
PF Motor
With the labeled area outward