EasyManua.ls Logo

Epson Stylus Photo RX585 - 4.2.3 Main Board Assy; Case Open Sensor

Epson Stylus Photo RX585
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Photo RX585/RX595/RX610 Revision B
Disassembly and Assembly Removal of Exterior Parts 66
4.2.3 Main Board Assy / Case Open Sensor
Removing the Case Open Sensor
1. Remove the Panel Assy (p.63)
2. Remove the Scanner Unit (p.65)
3. Remove the screw and remove the Case Open Sensor Assy. (Fig. 4-14)
4. Release the hook of the Case Open Sensor from the back side of the Case Open
Sensor Assy, and remove the Case Open sensor in the direction of the arrow.
(Fig. 4-15)
Removing the Main Board Assy.
1. Remove the Case Open Sensor Assy. (Fig. 4-14)
2. Disconnect all the FFCs and connectors from the Main Board. (Fig. 4-16)
3. Peel off the acetate tape (1).
4. Peel off the acetate tape (2) and remove the ferrite core on the Printhead FFC.
5. Remove the screws (x5), and remove the Main Board Assy by lifting its rear side.
(Continued to next page)
Figure 4-14. Removing the Case Open Sensor Assy
Figure 4-15. Removing the Case Open Sensor
Figure 4-16. Removing the Main Board Assy
A D J U S T M E N T
R E Q U I R E D
When the Main Board is to be replaced, back up the data in
EEPROM before starting disassembly, if possible. After assembly,
make the following adjustment.
5.2 Adjustment by Using Adjustment Program (p.101)
C A U T I O N
Since the Shield Plate may be burred, be sure to wear gloves to
avoid injury.
C.B.S-TITE 3x10 (x4)
Torque : 0.6±0.1N
·m
Case Open Sensor Assy
Hook
Back side
Case Open Sensor
3
1
2
4
5
C.B.S 3x6
Torque : 0.8±0.1N
·m
C.B.S-TITE 3x10 (x4)
Torque : 0.6±0.1N
·m
Acetate tape (2) and ferrite core
Acetate tape (1)