57
Chapter 3 Advanced Usage
Fixed Interface Model
DIP Switch Bank
Selecting the Print Density (DIP Switches 3/4)
SW Function ON OFF
Default
setting
1 Handshaking (BUSY condition) Receive buffer full
Offline
OFF
Receive buffer full
2 Reserved (Do not change setting) Fixed to OFF OFF
3
Selects print density
See the " Selecting the Print Density (DIP Switches 3/4)"
tabl
e below.
OFF
4
5 Reserved (Do not change setting) Fixed to OFF OFF
6 Reserved (Do not change settings) Fixed to OFF OFF
7 Reserved (Do not change settings) Fixed to OFF OFF
8 Reserved (Do not change settings) Fixed to OFF OFF
For DIP Switch 1 (BUSY condition), see also "Selecting the BUSY Status" on page 58.
Function SW 3 SW 4
Do not set ON ON
Print density (standard) OFF OFF
Print density (medium) ON OFF
Print density (dark) OFF ON
• If the print density is set to “Medium” or “Dark” level, print speed may be reduced.
• The print density can be set with DIP switches (3/4) or the software settings. (See "Software
Se
ttings" on page 59.)