55
Chapter 3 Advanced Usage
Parallel Model/Powered USB Model
DIP Switch Bank 1
∗1: For Parallel model only.
DIP Switch Bank 2
∗1: For Parallel model only.
∗2: For Powered USB model only.
SW Function ON OFF
Default
setting
1-1 Auto line feed Always enabled Always disabled OFF
1-2 Reserved (Do not change the setting) Fixed to OFF OFF
1-3
Selects paper sensors to output
paper-end signals (default value of a
command)*
1
Disabled
Roll paper end sensor
enabled, roll paper near-
end sensor enabled
OFF
1-4 Error signal output*
1
Disabled Enabled OFF
1-5
Undefined — OFF
1-6
1-7
1-8
SW Function ON OFF
Default
setting
2-1 Handshaking (BUSY condition) Receive buffer full
Offline
OFF
Receive buffer full
2-2 Reserved (Do not change setting) Fixed to OFF OFF
2-3
Selects print density
See the " Selecting the Print Density (DIP Switches 2-3/2-
4)" table below.
OFF
2-4
2-5
Reserved (Do not change setting) Fixed to OFF OFF
2-6 Reserved (Do not change settings) Fixed to OFF OFF
2-7 Reserved (Do not change settings) Fixed to OFF OFF
2-8
If pin 31 reset signal
*1
Fixed to ON ON
Reserved (Do not change settings) Fixed to OFF
*2
OFF
For DIP Switch 2-1 (BUSY condition), see also "Selecting the BUSY Status" on page 58.