EasyManuals Logo

Erbe APC 3 User Manual

Erbe APC 3
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11 / 70
2 Safety Instructions
80114-770_V23802
2021-01
Risks due to the environment
NOTICE
Unsuitable temperature or level of humidity during operation
If you operate the equipment at an unsuitable temperature or level of
humidity, it may sustain damage, fail, or not perform properly.
Operate the equipment at a suitable temperature and level of hu-
midity. You will find the tolerances for temperature and humidity
in the Technical Data.
If other ambient conditions must be observed for operation of the
equipment, you will also find them in the Technical Data.
NOTICE
Unsuitable temperature or humidity in transit or storage
If you transport or store the equipment at an unsuitable temperature
or level of humidity, it may sustain damage and fail.
Transport and store the equipment at a suitable temperature and
level of humidity. You will find the tolerances for temperature and
humidity in the Technical Data.
If other ambient conditions must be observed for transport and
storage of the equipment, you will also find them in the Technical
Data.
NOTICE
Insufficient acclimatization time, unsuitable temperature during
acclimatization
If the device was stored or transported below or above a certain tem-
perature, it will take a certain time and temperature to acclimatize.
If you do not observe the rules, the device can sustain damage and
fail.
Acclimatize the device according to the rules in the Technical Data.
NOTICE
Overheating of the device due to poor ventilation
If ventilation is poor, the device can overheat, sustain damage, and
fail.
Install the device in such a way that there is an unobstructed cir-
culation of air around the housing. Installation in confined wall re-
cesses is prohibited.
WARNING
Penetration of fluid into the device during operation or when
cleaning the device
Risk of electric shock to the medical personnel.
The unit may become damaged and fail.
Make sure no liquid can penetrate the device.
Do not place vessels containing liquids on top of the device.
If fluid has penetrated into the device, take the device out of op-
eration immediately. You can only start using the device again
once it has been checked by a service technician.

Table of Contents

Other manuals for Erbe APC 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Erbe APC 3 and is the answer not in the manual?

Erbe APC 3 Specifications

General IconGeneral
BrandErbe
ModelAPC 3
CategoryMedical Equipment
LanguageEnglish

Related product manuals