9 FAULT CODES
0459 287 601
- 31 -
© ESAB AB 2020
8
+15V power supply (wire feed unit and power unit)
The voltage is too high or too low.
1. Send for a service technician
8
+13V power supply (remote control unit)
The voltage is too high or too low.
1. Send for a service technician
9
-15V power supply (power unit)
The voltage is too high or too low.
1. Send for a service technician
9
+20V, +60V power supply (wire feed unit)
The voltage is too high or too low.
1. Send for a service technician
9
+10V power supply (remote control unit)
The voltage is too high or too low.
1. Send for a service technician
10
+24V power supply
The voltage is too high or too low.
1. Send for a service technician
11
Wire feed speed
The voltage is too high or too low.
1. Send for a service technician
12
Communication error (warning)
The load on the system CAN bus is temporarily too high.
The power unit or wire feed unit may have lost contact with the control panel.
1. Check the equipment to ensure that only one wire feed unit or remote control
unit is connected.
2. If the error is repeated, send for a service technician.
14
Communication error
The system's CAN bus has temporarily ceased to work due to excessive load.
The current welding process is stopped.
1. Check the equipment to ensure that only one wire feed unit or remote control
unit is connected.
2. If the error is repeated, send for a service technician.