9 FAULT CODES
0459 287 601
- 32 -
© ESAB AB 2020
15
Messages lost
The microprocessor is unable to process incoming messages sufficiently quickly,
with the result that information has been lost.
1. Turn off the mains power supply to reset the unit.
2. If the error persists, send for a service technician.
16
High open-circuit voltage
The open-circuit voltage has been too high.
1. Turn off the mains power supply to reset the unit.
2. If the error persists, send for a service technician.
17
Lost contact
The control panel has lost contact with the wire feed unit.
The current welding process is stopped.
1. Check the cables.
2. If the error persists, send for a service technician.
18
Lost contact
The control panel has lost contact with the power unit.
The current welding process is stopped.
1. Check the cables.
2. If the error persists, send for a service technician.
19
Incorrect settings values in external RAM
This fault will be detected if the information in the battery-backed memory has
become corrupted.
1. The fault will correct itself, but the data stored in the current memory position
will be lost.
20
Memory allocation error
The microprocessor is unable to reserve sufficient memory space.
This fault will generate fault code 26.
1. Send for a service technician
22
Transmitter buffer overflow
The control panel is unable to transmit information to the other units at a
sufficiently high speed.
1. Turn off the mains power supply to reset the unit.
23
Receiver buffer overflow
The control panel is unable to process information from the other units at a
sufficiently high speed.