9 FAULT CODES
0459 287 601
- 34 -
© ESAB AB 2020
43
The connected power source has not the latest software
U6 panel is connected to a power source that does not support regulator type 17.
1. Update power source software.
44
Memory management error
U6 panel has detected a mismatch between method data read from memory and
current data. Applicable to MIG/MAG welding in synergy mode.
1. Edit settings and store new values. Old values are obsolete.
45
Corresponding dip/spray line missing
The U6 panel has detected that the dip/spray line corresponding to the chosen
synergy line for pulse welding, is not available. Applicable only when using
synergy group 99 with user defined synergy lines.
1. Download the missing synergy line using ESAT and restart.