6 CONTROL PANEL
0463 933 001
- 28 -
© ESAB AB 2023
6.4.6 Hidden functions for MMA
Long press the parameter selection button to navigate the hidden MENU option (No welding). Select
the desired function one by one (RES, VER) by turning the left potentiometer knob and adjust the
value by turning the right potentiometer knob.
Left diplay letter Function Default Right display settings
VEN Version no. V4.0 -
RES Default settings No No/Yes
Version No. (VEN)
This function enables viewing the software versions of the connected system.
Reset (RES)
This function resets to the factory default settings. All saved jobs will be deleted as a result of the
reset.