D4 Gas Pipe Sizing
Gas pipe should be sized as per the requirements of AS/NZS 5601. The pipe sizing must be sucient
to deliver the following volume of gas to the heater with all other gas appliances in the home running at
the same time:
DF700 Gas Consumption = 25MJ/hr
DF960 Gas Consumption = 31MJ/hr
D5 Gas Pipe Position
The DF-Series fireplace gas pipe entry point is located in the lower right corner; a sheet of silicone is
used as a grommet (circled below).
Get the gas pipe lined up with the silicone grommet so that when the chassis is pushed into the cavity
in section E the fire will look like the diagram shown below.