B
A C D E F G SERVICE
48
S
Service Manual
IMPORTANT:
This appliance must be serviced every 12 months.
Any service operation should be carried out only by a suitably qualied and
trained person.
Gas and electricity supply MUST be isolated before any service operation is
carried out on this appliance.
This manual should be left with the appliance.
DO NOT MODIFY THIS APPLIANCE.
S1 Error Codes
This gas fire has been designed to show error codes to help explain and identify any fault situation that
occurs. These codes will appear on the remote in the form of a large letter “E” with a number beside it.
Codes can normally be reset by turning the fireplace o then on again at the mains power wall switch.
The following table shows what each code means and possible ways to rectify the situation. In the case
of persistent or repeated shutdown errors, action must be taken immediately to find and repair the
fault.
Error Code Suggestion action
Electronics Over
Temp
Excess lint and dust build-up on the front of the controller tray.
Fascia may be installed incorrectly resulting in restricted air flow.
The room air fan may be slowed or stalled. Remove firebox, check that
the fan is plugged in, cleaned, and free turning.
Note: This error has a permanent lock out and will require the unit to be reset
after the initial error (turning the power to the fire o “at the wall” then on
again after a few seconds).
Flame Failure or
Power Flue trip
The fire has tried to light three times and failed.
Check gas supply and check other gas appliances to see if they are af-
fected. If you have two separate propane cylinders, switch over to the full
bottle or contact your gas supplier. You may need to retry igniting the fire
a few times after re-establishing gas supply.
Check the flame impingement in relation to the flame rod. Ensure the
flame rod is well enveloped in flame as per the diagram in the installation
instructions and free of any surface contamination. Ensure no small em-
ber flakes have dropped onto the ignition electrodes between the burners.
Check that the fan inside the powerflue wall terminal is running during
startup. This fan may need servicing if it is slowed or stalled.