2.3 Procedure for Installation and Removal
1. Before you start, create ESD-compliant conditions
at your workplace.
2. Observe the following safety instructions and chap-
ter 2.3.1, 2.3.2, 2.3.3 and 2.3.4.
.
WARNING!
Danger - electromagnetic radiation!
During operation, the ES4455.2 Load Carrier Board and its populated
variants ES4450.3, ES4451.4, ES4452.1, ES4453.1, ES4457.1 and
ES4458.1 and loads connected to them, can emit electromagnetic
radiation, which can cause cardiac pacemakers or implanted defibril-
lators to malfunction or become damaged.
The products may only be operated in areas where persons with
pacemakers are prohibited from entering. The entrances to these
areas must bear sign P007 "No access for persons with cardiac pace-
makers or implanted defibrillators" in a clearly visible position in
accordance with ISO 7010:2011 "Registered Safety Signs".
Failure to observe this rule can lead to health hazards and even death
for persons with pacemakers and implanted defibrillators.
WARNING!
Danger from high voltages!
The components, plug connectors and conductor paths of the
ES4455.2 Load Carrier Board and its variants ES4450.3, ES4451.4,
ES4452.1, ES4453.1, ES4457.1 and ES4458.1 may have dangerous
voltages. These voltages can still be present even after the ES4455.2
and its variants ES4450.3, ES4451.4, ES4452.1, ES4453.1, ES4457.1
and ES4458.1 have been removed from the ES4408.1 Load Chassis,
the ES5300.1-A Housing or the ES5300.1-B Housing or if the
ES4408.1 Load Chassis, the ES5300.1-A Housing or the ES5300.1-B
Housing have been switched off.
Make sure that the products are protected from external contact
during operation. Switch off the ES5300.1-A Housing, the ES5300.1-
B Housing or the ES4408.1 Load Chassis and unplug from the mains.
Wait at least three minutes before removing the products.
Failure to do so poses a danger to life and health.
CAUTION!
Do not install any cards while the ES4408.1 Load Chassis, the
ES5300.1-A Housing or the ES5300.1-B Housing is switched on!

Table of Contents