ES4455.2 Load Carrier Board - User’s Guide48
Technical Data and Standards ETAS
Ambient Conditions
Power Supply
Dimensions
4.2 Meets Norms and Standards
The products meet the following norms and standards:
The board is only intended for use in industrial settings in accordance with EN
61326-1. Avoid potential radio interference when using the module outside of
the industrial settings with additional shielding measures!
Environment Use only inside enclosed and dry rooms
Max. contamination level 2
Temperature during operation 5 °C to 40 °C (41 °F to 104 °F)
Relative humidity 0 to 95% (non-condensing)
Operating altitude max. 2000 m above see level
max. current consumption
(mounted with load modules,
full load operation)
+ 3.3 V DC: 100 mA
+ 5V DC: 500mA
+12V DC: 400mA
Height 3 U
Width 14 HP
Depth 340 mm
Weight (ES4455.2) 0.5 kg
Weight (ES4450.3, ES4451.4,
ES4452.1, ES4453.1 and
ES4457.1)
4kg
Weight (ES4458.1) 2 kg
Standard Test
IEC 61326-1 Electrical equipment for measurement, control and laboratory
use –
EMC requirements (industrial setting)
IEC 61010-1 Safety requirements for electrical equipment for measurement,
control and laboratory use - Part 1: General requirements
This is class A equipment. This equipment can cause radio interfer-
ence in residential areas. Should that be the case, the operator may
be requested to institute reasonable measures.
The signal lines may not exceed a maximum length of 3 m!