16 Source 4WRD Installation and User Manual
Troubleshoot the Source 4WRD
The following error codes may be seen on the Source 4WRD user
interface. For more troubleshooting assistance, see
Help from ETC
Technical Services on page2
.
O t P (OTP) indicates that the fixture has gone into over-
temperature protection. Reset the fixture to clear the code.
For DMX mode: Return the DMX control to 0.
For AC mode: Remove the fixture from power for five seconds
and then restore power.
U t P (UTP) indicates that the fixture has gone into under-
temperature protection. Allow the fixture to warm to a
minimum of 5°C (41°F).
Flashing DMX address indicates loss of DMX.
Dark screen indicates loss of power or fixture time-out. In the
event of time-out, press any button to wake the user interface.
If this fails to wake the user interface, troubleshoot the power
loss:
Verify that all cables are fully seated and that power is
applied to the fixture.
If a working Source 4WRDLED is available, exchange the
Source 4WRDLED with the working Source 4WRDLED to
further isolate any issues.
If the fixture still does not respond, contact ETC Technical
Services for additional troubleshooting steps or to arrange a
repair. See
Help from ETC Technical Services on page2
for
contact information.