Not enough suction on the squeegee
81. Recovery tank is full
82. Lid on the exhaust pipe is open
83. Vacuum pipe disconnected
84. Vacuum pipe is clogged
85. Faulty vacuum pipe
86. Dirty squeegee
87. The squeegee is not adjusted properly
88. Material tangled with the squeegee blades
89. Squeegee blades either broken or worn out
90. The tank is either open or not properly closed
91. Damaged lid gasket
92. Faulty suction motor
93. Flat batteries
Empty the tank
Tight the lid
Verify that it is mounted properly
Clean the vacuum pipe
Replace the pipe
Clean the squeegee
Adjust inclination and pressure
Clean the blades
Reverse the blade or replace them
Close or verify the lid
Replace the gasket
Replace or check the motor
Recharge them
Front lights and side lights not working
94. Light faulty
95. Switch faulty
96. Fuse carrier 10A fuse pos.8 faulty
97. Transformer no. 2 faulty
98. Service supply remote switch faulty
Replace
Have it replaced
Replace it
Replace it
Have it replaced
99. Light faulty
100. Micro switch on brake pedal faulty
101. Fuse carrier 10A fuse pos.8 faulty
102. Transformer no. 2 faulty
103. Service supply remote switch faulty
Replace
Have it replaced
Replace it
Replace it
Have it replaced
Reverse lights not working
104. Light faulty
105. Reverse light relay faulty
106. Fuse carrier 5A fuse pos.7 faulty
107. Fuse carrier 10A fuse pos.6 faulty
108. Transformer no. 1 faulty
109. Service supply remote switch faulty
Replace
Have it replaced
Replace it
Replace it
Have it replaced
Have it replaced
Reverse buzzer not working
110. Buzzer faulty
111. Fuse carrier 10A fuse pos.6 faulty
112. Transformer no 1 faulty
113. Service supply remote switch faulty
Have it replaced
Replace it
Have it replaced
Have it replaced
Flashing lights not working
114. Lights faulty
115. Fuse carrier 3A fuse pos.5 faulty
116. Fuse carrier 10A fuse pos.6 faulty
117. Intermittence faulty
118. Transformer no.1 faulty
119. Service supply remote switch faulty
Replace
Replace it
Replace it
Have it replaced
Replace it
Have it replaced
Tank inspection cover does not open
120. Suction unit on
121. Toggle switch faulty
122. Toggle switch connector disconnected or badly
connected
123. Relay faulty
124. Fuse carrier 3A fuse pos.10 burnt out
125. Service supply remote switch faulty
126. Fuse carrier 30A fuse pos.3 burnt out
127. Actuator faulty
Switch off suction unit
Replace switch
Check the connector connection
Have it replaced
Replace it
Have it replaced
Replace it
Have it replaced