IMPORTANT! ANY TYPE OF MAINTENANCE SERVICE OR TEST, EXCEPT FOR THOSE DESCRIBED IN THE MANUAL,
MUST ONLY BE PERFORMED BY AN AUTHORIZED AFTER-SALES CENTRE (AAC)
Brush plate does not come out
128. Key detached
129. Fuse burnt out
130. Actuator faulty
131. Brush plate rotation pin blocked
Insert key
Replace
Replace
Remove and check pin. If damaged, replace.
132. Key detached
133. Main brush plate not lowered
134. Reset fuse tripped
135. Gear motor faulty.
Insert key
Lower the brush plate
Reset the fuse; if the problem continues, check
the causes.
Have it replaced.
136. Brush plate not lowered
137. LEDs on panel relating to water flow are not lit
up
138. Water control solenoid valve blocked or faulty.
139. Pipe clogged.
Lower the brush plate
Insert one or more LEDs on panel
Have it replaced.
Clean pipe
OPTIONAL