1143W24E4.00 · EV3 200 Web 03/2021
| 16 |
5.4 CONTROLLER OPERATION
5.4.1 Switching the controller ON/OFF
With the function enabled (POF=1),pressthe keyforatleast3secondstoswitchthecontrolleron/off.
Fig. 7. Main screen Fig. 8. Controller off
5.4.2 Unlocking the keypad
Afteraboutoneminuteofinactivity,thedeviceautomaticallylocksthekeypad(thecodeLoc appears for a few seconds).
Tounlockthekeypad,holddownanykeyforabout3secondsuntilthecodeUnLappearstoconfirmthekeypadhasbeen
unlocked.
3 s
Fig. 9. Keypad locked Fig. 10. Conrmation keypad unlocked
5.4.3 Setting/changing the setpoint
Withthekeypadunlocked,touchandreleasethe keytoaccessthesetpointmenu.Scrollthevalueswiththe or
keysandtouch to confirm the setpoint value.
12
Fig. 11. Accessing the setpoint menu Fig. 12. Changing the setpoint
5.4.4 Activating manual defrost
Withthekeypadunlocked,touchthe keyforatleast3secondstoactivatemanualdefrost.Thedefrosticonwillcomeon.To
deactivate,switchthedeviceoffandthenonagain.
3 s
Fig. 13. Activating manual defrost