1143W24E4.00 · EV3 200 Web 03/2021
| 21 |
Pb2
ON
SP
TEi-d19
SP+r0
OFF
Calibration Normal work
End of
calibration
Ideal evaporator
temperature (TEi)
Fig. 20. Modular defrost: Adaptive - start defrost due to temperature
6.2.5 Modular defrost: In real time (RTC)
Defrost In real time (RTC) is set with the following parameters:
Par. Description MU Range
d8
Defrost interval count mode. 4 = In real time (RTC).
--- 0...4
d9 Evaporation threshold for automatic defrost interval count. °C/°F -99.0...99.0
Hd1 Defrost 1 activation time. “- - - -"=Disabled. h ----,0...23
Hd2 Defrost 2 activation time. “- - - -"=Disabled. h ----,0...23
Hd3 Defrost 3 activation time. “- - - -"=Disabled. h ----,0...23
Hd4 Defrost 4 activation time. “- - - -"=Disabled. h ----,0...23
Hd5 Defrost 5 activation time. “- - - -"=Disabled. h ----,0...23
Hd6 Defrost 6 activation time. “- - - -"=Disabled. h ----,0...23
Hr0 Activatetheclock.0 = No; 1 = Yes. --- 0/1
Operation
ON
Hd1 Hd2 Hd3 Hd4
OFF
Fig. 21. Modular defrost: In real time (RTC)