Inter Com Fault
Internal Communication Fault
Ÿ Check the connection between inverter and BI connects
normally
Ÿ Or contact Panasonic Technical Support
Isolation Fault
Isolation Fault
Ÿ Check if the insulation of electric wires are damaged or too wet
Ÿ
Mgr EEPROM Fault
Manager EEPROM Fault
Ÿ
Other Device Fault
CPU Self-check Fault or Internal Flash Fault or RAM Fault
Ÿ
Over Temp Fault
Temperature over the limitation
Ÿ Check if the environment temperature is over limitation
Ÿ Check if the internal fan is fault
Ÿ
RC OCP Fault
Leakage Current Fault
Ÿ Check if the insulation of electric wires are damaged or too wet
Ÿ
UnderTemp Fault
Temperature Below the Limitation or Temperature Sensor Fault
Ÿ
Faults
Sample Fault
Gird Frequency or Voltage Sample Fault
Ÿ
Diagnosis and solution
Bat Break Open
Fault
Battery Break Open Fault
Ÿ Check if the circuit break of battery is open.
Fan Fault
Inverter Internal Fan Fault
Ÿ
SW OCP Fault
Battery Charge and Discharge Over Current Fault or PV Over Current Fault
or Inverter Over Current
Ÿ
RCD Fault
Residual Current Device Sensor Fault
Ÿ
Rtc Fault
SoftVerFault
Program Write Fails or Incorrent Program Written in
Ÿ Re-write the program
Ÿ
Rtc Fault
Ÿ
Faults
Diagnosis and solution
Grid Lost Fault
Grid Lost Fault
Ÿ System will reconnect if the utility is back to normal
Ÿ Check if the grid is normal
TZ Protect Fault
The Firmware of PV or Inverter or Battery Over Current Fault
Ÿ
Troubleshooting
Troubleshooting
109
108
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Please contact Panasonic Technical Support
Or contact Panasonic Technical Support
Or contact Panasonic Technical Support
Or contact Panasonic Technical Support
Or contact Panasonic Technical Support