7.2 Installation Methods
There are two alternative installation methods (wall mounting and floor mounting)
and several schemes available for users. For details, please refer to Section 7.1.
The following installation will take Scheme “base+four batterys+BMS+inverter+EV-SB”
mounting on the wooden wall with studs spaced at 32 in / 812.8 mm as an
example.
7.3 Floor-mounting
Step 1: Mount the battery
a) Remove the dust cover of the base;
NOTE!
A distance of at least 19.68 in / 500 mm shall be set aside on both
sides of the whole system.
WARNING !
During installation, please make sure battery port is not short-circuited.
Mechanical InstallationMechanical Installation
39
38
Weight and mounting height instructions
1263 mm
49.72 in
Weight(lb/kg): 353/160
844 mm
33.23 in
808 mm
31.81 in
2 Batteries
Inverter
BMS
Battery
Battery
Base
Weight(lb/kg): 591/268
844 mm
33.23 in
1408 mm
55.43 in
1863 mm
73.35 in
4 Batteries
Inverter
BMS
Battery
Battery
Base
Battery
Battery
Weight(lb/kg): 472/214
844 mm
33.23 in
1108 mm
43.62 in
1563 mm
61.54 in
3 Batteries
Inverter
BMS
Battery
Battery
Base
Battery
CAUTION!
Please re-mount the dust cover to the battery module before drilling
holes to avoid dust falling into the interface and do remember
remove the dust cover again after the installation wall bracket
completed.