Specification
11
Specification
3.2 Specification of Battery
10
Q.+ BAT-G1
Nominal Voltage [Vdc)
Operating Voltage [Vdc)
Nominal Capacity [Ah)
Max. Charge/Discharge Current (A)
Recommend Charge/Discharge Current (A)
153.6
135-174
100
54
50
System Roundtrip Effciency(0.2C,25°C/77°F)
Expected Lifetime(25°C/77°F)
Cycle Life90% DOD(25°C/77°F)
AC: 89% / DC: 94%
12 years
6000 cycles
Model
Nominal Energy [kWh)
15
Usable Energy 90% DOD [kWh)
13.5
90-116
100
54
50
102.4
10
9.0
180-232
100
54
50
20
18.0
204.8
Storage Temperature
Ingress Protection
IP65
-4°F~86°F/-20°C~30°C (12 months)
86°F~122°F/30°C~50°C (6 months)
Charge Temperature
Discharge Temperature
32°F~127.4°F/0°C~53°C
-14°F~127.4°F/-10°C~53°C
EV-X10
EV-X15
EV-X20
3.3 Specification of SmartBox
Battery Input/Output
Efficiency, Power Consumption and Standard
Environment Limit
Reverse-Polarity Protection
Model
Battery type
Input/output voltage range [V]
Rated input/output voltage [V]
Maximum input power [W]
Maximum output power [W]
Maximum Input/output current [A]
Li-ion
75-450
150
8094
54
Yes
Cycle efficiency charging to
7600
discharging (PCS Only)
92.5%
Internal consumption(night) [W]
<3W
UL1741,UL1741 SA,UL1699B, CSA C22.2 No. 107.1-16,
CSA - C22.2 No. 292-18
Power consumption
Safety
EMC
Certification
RoHS
CEC Weighted Efficiency
97.5%
Model
Maximum Inverter Efficiency
98.0%
(PV to GRID)
Standard
FCC part15 class B
IEEE1547, Rule 21,Rule14 (HI)
Yes
Environment limit
Storage temperature Range [°F (°C)]
Protection class
Operating Temperature Range [°F (°C)]
De-rating start temperature [°F (°C)]
NEMA 4X
–13 to +140 (–25 to +60)
113 (45 ) or above
–13 to +167(–25 to +75 )
Over voltage category
Humidity [%]
Altitude [ft (m)]
Noise emission(typical) [dBA]
0%–95% RH
9843 (3000) MAX
<30
IV (electric supply side), II (PV side)
EVHB-I7
EVHB-I7
EVHB-I7
Q.+ BAT-G1
AC Output Voltage (Nominal) [Vac]
AC Output Voltage Range [Vac]
AC Frequency (Nominal) [Hz]
120/240 Split Phase
105.5-132 / 211-264
60
Grid Input / Output to Main Distribution Panel at Grid Tie
AC Frequency Range [Hz]
59.3-60.5
AC Short Current (RMS)
22000
Q.+ BAT-G1
AC Output Voltage(Nominal) [Vac]
AC Output Voltage Range [Vac]
AC Frequency(Nominal) [Hz]
AC Current Output (Max) [A]
120/240 Split Phase
105.5-132 / 211-264
60
160
Output to Main Distribution Panel at Backup Operation
AC Frequency Range [Hz]
59.3/60.5
Max. Continuous Current [A]
160