4. Site Requirements and Pre-installation Guidance
The installation of EVERVOLT Home Battery system including EVHB inverter,
battery and SmartBox must be done in accordance with local codes and
the National Electric Code (NEC) ANSI / NFPA 70 or the Canadian Electrical Code CSA C22.1.
Specification
Site Requirements and Pre-installation Guidance
4.1 Physical Requirements
12
The whole system requires adequate clearance for the installation, cabling or conduit
and airflow. Do not install anything above each unit that limits access to the unit or that
might fall and damage the unit. Do not mount each unit upside down.
The inverter and battery in the system can be wall-mounted or floor-mounted.
The SmartBox in the system must be wall-mounted and recommended to install on the
right side of inverter. It needs to be configured for cable entry at the bottom and sides of
Each unit has a mounting bracket to support it. Mounting requirements based on wall
type are provided in Section 7.1.
Figure 1 Dimensions of inverter
32.95 in
837 mm
1
5
.
7
4 in
400 m
m
5.74 in
146 mm
4.2 Dimensions of the System
13
CSA C22.2 No.29, CSA22.2 205, CSA 22.2 0.19
UL1741, CSA 22.2 NO.107, IEC62109-1, UL67, UL916, UL869A
Q.+ BAT-G1
Maximum input overcurrent
Maximum continuous input current [A]
125
100
Generator
protection device [A]
Q.+ BAT-G1
Auto generator start
Yes
Maximum AC power [W]
24000
Q.+ BAT-G1
Number of “Smart Load 50A” branch [120V]
4
Smart Load
Q.+ BAT-G1
Combine 120V branches to 240V branch
Yes
Number of “Smart Load 80A” branch [120V]
2
Q.+ BAT-G1
Number of communication RS485 ports
2
General Info
Q.+ BAT-G1
LED display
3
Number of dry contact
4
Q.+ BAT-G1
Maximum elevation [feet / m]
9842/3000
Q.+ BAT-G1
Noise [dB] < 40
Weight [lbs / kg]
99.2/45
Q.+ BAT-G1
Protection rating
NEMA 3R
Q.+ BAT-G1
Dimensions [H x W x D] [in / mm] 34.3 x 22.9 x 9.1 / 870 x 580.6 x 247.1
Operating temperature range [°F / °C]
-13 to +113 / -25 to +45
Q.+ BAT-G1
Warranty [years]
12
Standard Compliance
Q.+ BAT-G1
Emissions
FCC part 15 Class B
Safety
Q.+ BAT-G1
Nominal AC Frequency [Hz]
Maximum continuous current [A]
60
160
Non-Backup Port
Q.+ BAT-G1
Nominal AC Voltage
120/240 Vac split phase
Q.+ BAT-G1
Nominal AC Frequency [Hz]
Maximum continuous current [A]
60
64
Solar
Nominal AC Voltage
120/240 Vac split phase
the enclosure.