EasyManua.ls Logo

Evinrude E-TEC E150DPXSCF - Tachometer Pulse Setting; Water Pump Overboard Indicator; Operating Temperature; Break-In

Evinrude E-TEC E150DPXSCF
445 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
INSTALLATION AND PREDELIVERY
RUNNING CHECKS
2
Tachometer Pulse Setting
Confirm accuracy of tachometer reading.
Adjust dial on back of tachometer to required
setting (the outboard should not be running).
Water Pump Overboard Indicator
A steady stream of water should flow from the
overboard indicator.
Operating Temperature
An outboard run at idle speed should achieve a
temperature based on the engine’s thermostatic
control. In general, the powerhead temperature
should reach at least 104°F (40°C) after five min-
utes of idling. Check that the powerhead reaches
idle temperature. Refer to SERVICE SPECIFICA-
TIONS on p. 10.
Idle Speed
Make sure the outboard idles within the specified
idle RPM range. If the outboard is run on a flush-
ing device, the idle speed and quality may not be
representative of actual in water use.
Break-In
When the outboard is delivered, refer the cus-
tomer to the break-in information in the Opera-
tors Guide.
The Engine Management Module (EMM) auto-
matically supplies extra oil to the engine during
the first five hours of operation, above 2000 RPM.
Use the diagnostics software to confirm that the
break-in program has been started. Refer to Oil
Control Settings on p. 106.
Outboard Model Tachometer Setting
40–250 HP 6 Pulse or 12 Pole
1. Water pump overboard indicator DRC4952
1

Table of Contents