28
AUTOMATIC BALING (PHOTO EYE CONTROLLED)
1. Turn the BALER power disconnect to ON.
2. Turn the SYSTEM key switch to AUTO.
3. Turn the PHOTO EYE CONTROL switch to ON.
When photo eye beam is broken, the baler starts and cycles automatically, without warning.
4. Depress FORWARD or REVERSE to activate auto cycle.
5. Load the feed chamber.
The baler cycles automatically when the feed chamber becomes full.
6. Continue filling the chamber. When a complete bale is formed, the blue BALE TIE OFF LIGHT at the top of the baler
illuminates.
7. After the blue BALE TIE OFF LIGHT illuminates, turn the PHOTO EYE CONTROL switch to OFF. Follow the Bale Tying
and Bale Ejection instructions earlier in this section.
8. If you wish to stop baling before a bale is completed, turn the PHOTO EYE CONTROL switch to OFF, then the SYSTEM key
switch to OFF.
Never leave the baler unattended with the Photo Eye Control On.