EasyManua.ls Logo

Excel EX62 - Semiannual Care Requirements; Yearly Care Requirements

Excel EX62
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
22. After the first week of use, check the tightness of all the wires and monthly thereafter.
This check should be done by a qualified electrician.
MONTHLY CARE REQUIREMENTS
1. Disconnect and lock out power to the baler. Check the tightness of all wires.
This check should be done by a qualified electrician.
2. Change the oil filter and breather filter after every 3 months or every 500 hours of operation.
SEMIANNUAL CARE REQUIREMENTS
1. The motor is equipped with double shielded ball bearings having sufficient grease to last indefinitely under normal service.
Where motor is used constantly is dirty, wet, or corrosive atmospheres, add one quarter ounce of grease per bearing every three
months. Use a good quality rust inhibited polyuria based grease, such as Chevron SRI.
2. Check the wear liner. Liners showing excessive wear should be replaced.
3. Inspect the shear edge. Remove the bolts and rotate to a clean edge if necessary. See the section entitled ADJUSTMENTS.
4. Check the platen to shear edge clearance. Make adjustments if necessary. Check the nylatron wear pads which the platen rides
upon. See the Platen to Cutting Edge Clearance Adjustment instructions in the section entitled ADJUSTMENTS.
5. Check the alignment of the wire guide slots in the platen with the wire guide slots in the baler floor. See the section entitled
ADJUSTMENTS. Inspect the condition of the side bearings.
6. A qualified service technician shall check and record pressure settings of the pressure switch, pump compensator and relief
valve.
7. Check motor to pump coupler to ensure it is not separating.
YEARLY CARE REQUIREMENTS
1. A qualified electrician or service technician must check all electrical connections and check motor resistance. Recording
successive readings helps to prevent future failure.
2. Have an oil sample tested yearly and compare the result to the oil manufacturer's specifications. If oil does not meet
specifications, replace. 105 gallon of oil as recommended in the Oil Selection Table on page 24 is required to fill the reservoir.
SERVICE KITS
1. EX62 6 Month Service Kit: (A-1117)
(1) HP-1049 Breather Filter
(1) HP-1015 Oil Filter element
(12) M-2039 Floor Shim
(2) M-2046 Side Shim

Related product manuals