2-1-1 Power-save Timer Settings
2-1-2 Automatic Power-off Timer Settings
LCD displays the current configuration
Use MODE or HOLD key to enter a parameter
Default setting = 0 (power-save off)
1 ~9 The scale will automatically enter the
power-save mode after 1 ~ 9 minutes
without operation.
Press TARE key
Press TARE key
Under WEIGHING MODE, the crane will enter power-save mode if
the weight on the hook is less than 10d external value or nega-
tive weight and the scale has no operation after 1 to 9 minutes.
After the crane enters power save mode, press any key or the
weight is more than 10d external weight, the crane will return
to previous mode.
LCD displays the current configuration
Use MODE or HOLD key to enter a parameter
Default setting = 0 (Auto power-off disabled)
1 When the scale is idle for 1 minute, the scale
automatically switches off.
2 When the scale is idle for 2 minutes, the scale
automatically switches off.
9 When the scale is idle for 9 minutes, the scale
automatically switches off.
Press TARE key
Press TARE key
Definition of no operation
No key is pressed or the weight is less than 10d external weight.
Under weighing mode, the crane will be power-off automatically if the weight
on the hook is less than 10d external value or negative weight and the scale
has no operation after 1 to 9 minutes.
MODE Upward digit selecting (0-9)
HOLD Downward digit selecting (9-0)
ZERO No function
TARE Confirm