EXCELL PRECISION CO., LTD.
45046
17
ZSME300000343
Hold Mode Operating Description
General Situation
FNC03 Set Point Control is active
Hold Condition
Exit Condition
Hold Condition
Exit Condition
Hold 0
Press the HOLD key
to hold the weight
value when required.
Press any key to exit
the hold mode.
Hold manually and
FNC03 is inaccessible
when Hold.
Press any key to exit
the hold mode. After
exit HOLD, FNC03 will
restart if the weight
vale is more than set
point control value.
Hold 1
No manual hold
function.
Under weighing mode,
the weight value is not
negative and exceeds
10d external value, the
crane will hold the
biggest weight
automatically in the
changing weight value.
Press any key to
exist the hold mode.
After the weight is
stable, manual hold
will be accessible and
FNC03 is inaccessible
when hold.
No auto hold function.
Press any key to
cancel hold function.
When add weight, the
hold function will
cancel automatically.
After canceling the hold
function, the FNC03
will restart if the weight
value is more than set
point control value.
Hold 2
No manual hold
function.
Under weighing mode,
the weight value is not
negative and exceeds
10d external value, the
crane will hold the
biggest weight
automatically in the
changing weight value.
The crane will cancel
the hold function
automatically if the
weight value is less
than 10d external
weight value.
After the weight is
stable and exceeds
10d, the manual hold
function is available
and the FNC03 will
stop.
No auto hold function.
The hold function will
be cancelled if add the
weight value or the
weight is less than 10d
external value. After
canceling the hold
function, the FNC03
will restart if the weight
value is more than set
point control value.
Hold 3
Under weighing mode,
press hold key to
choose manual hold or
the weight value is not
negative and exceeds
10d external value.
After the crane is
stable, the crane will
hold the displayed
weight value
automatically in
changing weight value.
Press any key to
cancel hold function.
Manual hold function
is available and
FNC03 will stop.
No auto hold function.
Press any key to
cancel hold function.
After canceling, the
weight value is more
than set point control
value and FNC03 will
restart.
Hold 4
Under weighing mode,
press hold key to
choose manual hold or
weight value is not
negative and exceeds
10d external value.
After the crane is
stable, it will hold the
displayed weight value
automatically in the
changing weight value.
The crane will cancel
the hold function
automatically after
the weight value is
less than 10d
external value.
Manual hold function
is available if the
weight value is more
than 10d external
value and FNC03 will
stop.
No auto hold function.
The hold function will
cancel if the weight is
less than 10d external
value.