EasyManua.ls Logo

EXFO FTB-1v2 - Page 434

EXFO FTB-1v2
497 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IEEE 488.2 and Specific Command Reference
422 FTB-1v2 and FTB-1v2 Pro
Specific Commands
:SYSTem:ERRor[:NEXT]?
Description The SYSTem:ERRor[:NEXT]? queries the
error/event queue for the next item and removes
it from the queue. The response message
consists of two fields separated by commas
<Code>,<Description[,Info]>.
SYSTem:ERRor[:NEXT]? is a query only and,
therefore, does not have an associated *RST
state.
Syntax :SYSTem:ERRor[:NEXT]?
Parameter(s) None
Response Syntax <Code>,<Description[,Info]>
Response(s)
Code:
The response data syntax for <Code> is defined
as a <NR1 NUMERIC RESPONSE DATA>
element.
The <Code> is a unique integer in the range
[-32768, 32767]. All positive numbers are
instrument-dependent. All negative numbers are
reserved by the SCPI standard with certain
standard error/event codes described in an
appendix of this document. The zero value is
also used to indicate that no error or event has
occurred.
Description[,Info]:
The response data syntax for
<Description[,Info]> is defined as a <STRING
RESPONSE DATA> element.

Table of Contents

Other manuals for EXFO FTB-1v2

Related product manuals